punch list missed.
Send us photos and your tracking list. Get a written findings report within 24 hours* — before your inspector or auditor does.
— any industry with field inspections in Bend.
$250, one time · Nothing new, no charge · You keep the report either way
*Depending on availability. We'll confirm turnaround when you submit.
Bend enforces Oregon Structural Specialty Code with heightened seismic provisions due to its proximity to the Cascadia subduction zone. High-desert climate demands strict energy envelope standards and snow load calculations. Wildfire-urban interface zones require ignition-resistant construction. CodeBuddy reviews Bend plans for $250 with 24-hour turnaround, covering seismic detailing, energy code, and wildfire-interface compliance.
Prepared for Acme Mechanical Inc.
Location
Bend, OR
Date
Aug 8, 2026
Trade
Electrical
Findings
Penetration seal not matching approved submittal — visible gap at fire-rated assembly
Checked against: Company SOP 4.2
Fastener pattern deviates from manufacturer data sheet — 6" OC required, measured at 9" OC
Checked against: Project Spec 08-31
Working clearance below required minimum at panel — 30" required, 22" measured
Checked against: Applicable Standard
Page 1 of 4
Trusted by teams at
Three steps. Five minutes.
Submit your job, and our patent-pending AI technology reviews every photo against your standards, specs, and existing tracking.
Tell us about the job.
Project name, address in Bend, and primary trade or discipline. We look up the applicable standards and regulations automatically from the address.
Send your photos and open items.
Upload directly, share a Drive/Dropbox link, or email them over. Your existing tracking sets the bar — anything already on it doesn't count as a finding.
Our patent-pending technology and AI system analyze every photo.
Cross-references each image against your specs, the applicable standards, and your existing tracking — helping identify deviations your list may have missed.
Get your report within 24 hours*.
Each finding includes the photo, the exact location, and the code section or spec it deviates from. Sorted by severity so you know what to fix first.
Built by Code Buddy.
Code Buddy is an AI-powered compliance platform used by thousands of field professionals across construction, energy, manufacturing, and fleet operations. Our patent-pending technology checks job site photos against codes, specs, and standards — the same technology that powers this report.
Built for the people who actually do the work.
Industries supported
Report turnaround
If nothing new identified
The kind of things we help catch.
Examples based on past reports. Each finding includes the photo, location, and the reference it was checked against.
Roof truss design lacks required 40 psf ground snow load capacity per Bend's high-desert elevation classification
Exterior siding in wildfire-urban interface zone does not meet Class A ignition-resistant material requirements
Heating system duct insulation below R-8 minimum required for Bend's climate zone 5 dry designation
Hold-down anchor bolt spacing exceeds maximum for seismic design category D lateral force resistance
Solar panel conduit penetrations through roof lack required fire-rated sealant at wildfire interface parcels
Exterior hose bibb missing required freeze-proof stem length for cold-dry climate winter conditions
And only if we identify something that wasn't already on your list.
If everything identified was already on your list, you pay nothing. You keep the report either way.
GET STARTEDLimited spots each week.
Every report is reviewed by a QA professional before delivery — not just generated and sent. That human review step means we can only take a limited number of jobs per week. Submissions are reviewed in the order they're received, and we'll let you know upfront if your report will take longer than 24 hours.
Before you ask.
What snow load does Bend require for residential roof design?
Bend requires a minimum 40 psf ground snow load for most residential structures, with higher values at elevated sites. Roof geometry and drift considerations may increase local requirements based on the Oregon Structural Specialty Code.
Does Bend have wildfire-interface building requirements?
Yes. Properties within Bend's designated wildfire-urban interface zones must use ignition-resistant exterior materials, maintain defensible space, and comply with Oregon fire code provisions for Class A roof assemblies and ember-resistant vents.
What energy code applies to new construction in Bend?
Bend follows the Oregon Energy Efficiency Specialty Code. As a climate zone 5 dry location, Bend requires higher insulation values, tighter air sealing, and verified HVAC efficiency compared to western Oregon cities.
How does seismic design affect Bend building permits?
Bend falls within seismic design category D due to Cascadia subduction zone proximity. Structural plans must show compliant lateral force systems, hold-downs, and foundation anchorage per the Oregon Structural Specialty Code.
How fast can I get a Bend plan review from CodeBuddy?
CodeBuddy delivers Bend plan reviews within 24 hours for $250. Reviews cover structural, energy, fire, and seismic compliance against current Oregon specialty codes and any Bend-specific amendments.