Scranton, Pennsylvania
Find what your
punch list missed.
Send us photos and your tracking list. Get a written findings report within 24 hours* — before your inspector or auditor does.
— any industry with field inspections in Scranton.
$250, one time · Nothing new, no charge · You keep the report either way
*Depending on availability. We'll confirm turnaround when you submit.
Scranton enforces the PA Uniform Construction Code in a region where former anthracite coal mining has left subsurface voids that affect foundation design and site stability. The city's older housing stock along the Lackawanna River corridor, combined with heavy northeastern Pennsylvania snowfall and freeze-thaw cycles, creates inspection requirements distinct from other PA cities. Code Buddy's Inspection Readiness Report is $250 with 24-hour turnaround, screening for mine subsidence and cold-climate compliance issues.
Prepared for Acme Mechanical Inc.
Location
Scranton, PA
Date
Aug 8, 2026
Trade
Electrical
Findings
Penetration seal not matching approved submittal — visible gap at fire-rated assembly
Checked against: Company SOP 4.2
Fastener pattern deviates from manufacturer data sheet — 6" OC required, measured at 9" OC
Checked against: Project Spec 08-31
Working clearance below required minimum at panel — 30" required, 22" measured
Checked against: Applicable Standard
Page 1 of 4
Trusted by teams at
Three steps. Five minutes.
Submit your job, and our patent-pending AI technology reviews every photo against your standards, specs, and existing tracking.
Tell us about the job.
Project name, address in Scranton, and primary trade or discipline. We look up the applicable standards and regulations automatically from the address.
Send your photos and open items.
Upload directly, share a Drive/Dropbox link, or email them over. Your existing tracking sets the bar — anything already on it doesn't count as a finding.
Our patent-pending technology and AI system analyze every photo.
Cross-references each image against your specs, the applicable standards, and your existing tracking — helping identify deviations your list may have missed.
Get your report within 24 hours*.
Each finding includes the photo, the exact location, and the code section or spec it deviates from. Sorted by severity so you know what to fix first.
Built by Code Buddy.
Code Buddy is an AI-powered compliance platform used by thousands of field professionals across construction, energy, manufacturing, and fleet operations. Our patent-pending technology checks job site photos against codes, specs, and standards — the same technology that powers this report.
Built for the people who actually do the work.
Industries supported
Report turnaround
If nothing new identified
The kind of things we help catch.
Examples based on past reports. Each finding includes the photo, location, and the reference it was checked against.
New construction in Scranton mine subsidence zone missing DEP mine subsidence insurance documentation and engineered foundation design
Floor joists in 1920s Lackawanna County wood-frame house sistered without matching original joist depth creating uneven bearing plane
Water service line transition from galvanized steel to copper uses dielectric union but lacks support bracket within 12 inches of fitting
Low-slope roof drainage design does not account for Scranton 40 psf ground snow load plus rain-on-snow surcharge per PA UCC
Wood-burning stove installation clearance to combustible wall at 30 inches does not meet 36-inch minimum without approved heat shield
Service upgrade to 200-amp panel in Scranton duplex lacks required grounding electrode system bonded to metal water pipe and driven rod
And only if we identify something that wasn't already on your list.
If everything identified was already on your list, you pay nothing. You keep the report either way.
GET STARTEDLimited spots each week.
Every report is reviewed by a QA professional before delivery — not just generated and sent. That human review step means we can only take a limited number of jobs per week. Submissions are reviewed in the order they're received, and we'll let you know upfront if your report will take longer than 24 hours.
Before you ask.
How does mine subsidence affect building permits in Scranton?
Scranton sits within Pennsylvania's anthracite coal region, and many properties overlay abandoned mine workings. The building department may require a mine subsidence risk assessment and engineered foundation design for new construction. The report flags when your project site falls within a known mine subsidence area.
What snow load requirements apply to Scranton buildings?
Scranton's ground snow load under PA UCC is approximately 40 psf, higher than many southern Pennsylvania jurisdictions. The report verifies that roof framing, truss designs, and connection details are adequate for this load plus required drift and rain-on-snow surcharge calculations.
Does the report check for Lackawanna River flood zone compliance in Scranton?
Yes. Properties near the Lackawanna River and its tributaries in Scranton may fall within FEMA flood zones requiring elevated construction, flood-resistant materials, and mechanical equipment placement above base flood elevation. The report identifies applicable flood zone requirements for your site.
Can Scranton property owners use third-party inspectors?
Under PA UCC, property owners in Scranton may contract with approved third-party inspection agencies for both plan review and field inspections. The report prepares your project for the specific compliance items these agencies and the Scranton building department prioritize during inspections.
What is included in the $250 Scranton Inspection Readiness Report?
The report delivers a full PA UCC compliance review within 24 hours, with Scranton-specific checks for mine subsidence foundation requirements, cold-climate snow and frost provisions, aging housing stock structural conditions, and Lackawanna County radon mitigation compliance.
Also in Pennsylvania